Key Features
| Parameter | Specification / Description |
|---|---|
| Product Architecture | Single-output enclosed type AC/DC switching power supply |
| Input Voltage Range | AC 10V–240V, 50Hz, |
| Input Current | ≤12A @ 110V–264Vac full load |
| Power Factor | ≥0.5 @ 110Vac/240Vac full load, compliant with IEC61000-3-2:2014 harmonic standard |
| Output Specification | DC 24V / 41.67A, continuous output power 1000W |
| No-load Power Consumption | ≤3W |
| Ripple & Noise | ≤200mV |
| Cooling Method | Built-in intelligent temperature-controlled fan (auto start/stop), integrated aluminum alloy heat sink |
| Protection Modes | SCP (Short Circuit Protection) / OLP (Overload Protection) / OVP (Over Voltage Protection) / OTP (Over Temperature Protection) / OCP (Over Current Protection) / SPD (Surge Protection) |
| Operating Environment | Temperature 0°C ~ +40°C, Relative Humidity 20%RH ~ 80%RH |
| Storage Environment | Temperature -20°C ~ +70°C, Relative Humidity 10%RH ~ 90%RH |
| Burn-in Test | 100% full-load burn-in tested |
| MTBF | ≥50,000 hours |
| EMI (Electromagnetic Interference) | EN55032:2015 Class B, VCCI Class B, GB 9254-2008, IEC61000-3-2:2014 |
| EMS (Electromagnetic Susceptibility) | IEC61000-4-2 ESD (Contact ±8kV / Air ±15kV), IEC61000-4-3 RS (3V/m), IEC61000-4-4 EFT (±2kV), IEC61000-4-5 Surge (±1kV DM / ±2kV CM), IEC61000-4-6 CS (3V), IEC61000-4-11 DIPS |
| Dielectric Strength | Primary to Secondary: 3000Vac / 5mA Max / 60s; Primary to Metal Housing: 1500Vac / 5mA Max / 60s |
| Leakage Current | ≤0.25mA @ 240Vac / 50Hz |
| Insulation Resistance | ≥50MΩ @ Primary to Secondary, test voltage 500Vdc |

Specifications
- Model
- LS-1000-24
- Input
- 110-240V 12A 47-63HZ
- Outpu
- 24V 41.7A
- Totel
- 1000W
- N.W
- 1.4kg
- Size
- 234×120×40mm
Related Products
View all →Need a custom order or bulk quote?
We offer OEM/ODM services and ship worldwide. Contact our sales team today.